Analysis of blood flow energy characteristics of pulsatile and non-pulsatile flow during extracorporeal circulation

Zhonghua wai ke za zhi [Chinese journal of surgery]
Zhen GuoZ Y Xu

Abstract

Objective: To analyze the magnitude of blood flow energy and characteristics of frequency domain between pulsatile flow and nonpulsatile flow during cardiopulmonary bypass and physiological flow. Methods: From January 2017 to December 2017, 60 cases of patients with mitral valve disease scheduled for mitral valve replacement or repair at Department of Cardiasurgery, Shanghai Chest Hospital, Shanghai Jiaotong University were randomly divided into 2 groups: pulsatile perfusion (PP) and non-pulsatile perfusion (NP). The magnitude of blood flow energy during pulsatile and non-pulsatile was calculated using energy equivalent pressure (EEP) and surplus hemodynamic energy (SHE) while fast Fourier transformation (FFT) was used to perform power spectral density analysis to identify the frequency domain characteristics between artificial and physiological flow (prior to CPB). The data was analyzed by analysis of variance or t test. Results: At the different time-points after occlusion, the EEP and SHE in PP group were respectively 1.52 to 1.62 and 2.03 to 2.22 times higher than NP at the distal of artery filter. The power density analysis revealed that the blood flow energy of physiological pulsatile flow patterns was within 40 Hz and th...Continue Reading