To devise and test an occluding coil anchoring system to improve the safety of coil embolization. The anchoring system was attached to Gianturco embolization coils and investigated in 15 pigs. In the short-term studies, one 0.035-inch anchored coil (15-18 cm in length and 7-10 mm in diameter) was placed in the infrarenal portion of the abdominal aorta in each of 12 pigs with use of an 8-F catheter from the carotid approach. Aortography was performed before and up to 4 hours after coil placement. In the long-term studies, 0.028-inch anchored coils (8 cm in length and 5 mm in diameter) were placed in the left femoral and the right carotid arteries in each of three pigs with use of a 6-F catheter positioned from the right femoral approach. One week later, the animals were evaluated angiographically for coil migration and vascular occlusion. Radiographically, the coils created a compact conglomerate on placement in all but one of the animals. No coil migration was noted during follow-up. Necropsy confirmed compact arrangement of the coils within the vessels and revealed effective anchoring of the device in all cases. The anchoring coil has proved effective in making coil embolization safer, especially in a high-flow arterial model.

References

Mar 15, 1992·The American Journal of Cardiology·P A CambierJ W Moore
Jul 1, 1992·Journal of the American College of Cardiology·S B PerryJ E Lock
Nov 1, 1991·Journal of Vascular and Interventional Radiology : JVIR·M A Mauro, P Jaques
Feb 1, 1991·Journal of Vascular and Interventional Radiology : JVIR·J J ChomynJ D Durham
Feb 1, 1991·Journal of Vascular and Interventional Radiology : JVIR·D S LeveyM J Pentecost
Nov 1, 1986·Radiology·F ButtoK Amplatz
Jan 1, 1986·Radiology·J HawkinsI F Hawkins
Oct 1, 1981·Radiology·W R Castaneda-ZunigaK Amplatz
May 1, 1980·Radiology·V P ChuangC Gianturco
Nov 1, 1995·AJR. American Journal of Roentgenology·J A DuttonD J Allison
Mar 1, 1996·Cardiovascular and Interventional Radiology·J F Reidy, S A Qureshi
Mar 1, 1997·European Heart Journal·A CelikerM Tynan

❮ Previous
Next ❯

Citations

Feb 8, 2005·Cardiovascular and Interventional Radiology·A Kónya, K C Wright
Sep 13, 2006·Cardiovascular and Interventional Radiology·Toshiyuki Irie
Mar 10, 2001·Current Treatment Options in Cardiovascular Medicine·Inder S. Anand, Viorel G. Florea
Jan 8, 2000·Catheterization and Cardiovascular Interventions : Official Journal of the Society for Cardiac Angiography & Interventions·A LimsuwanA Rothman

❮ Previous
Next ❯

Related Concepts

Related Feeds

Cajal Bodies & Gems

Cajal bodies or coiled bodies are dense foci of coilin protein. Gemini of Cajal bodies, or gems, are microscopically similar to Cajal bodies. It is believed that Cajal bodies play important roles in RNA processing while gems assist the Cajal bodies. Find the latest research on Cajal bodies and gems here.

Related Papers

Journal of Vascular and Interventional Radiology : JVIR
A Kónya, K C Wright
Cardiovascular and Interventional Radiology
P A NancarrowJ E Lock
© 2022 Meta ULC. All rights reserved