PMID: 16626542Apr 22, 2006Paper

Arsenic trioxide eluting stents to prevent restenosis of injured iliac arteries in rabbits

Zhonghua xin xue guan bing za zhi
Wei YangYong-lin Huang

Abstract

To assess the efficiency of eluting stent coated with arsenic trioxide (As(2)O(3)) suspended in poly-L-lactic acid (PLLA) to prevent in-stent restenosis in rabbits. Forty-five male New Zealand white rabbits were assigned to three groups (n = 15 for each group) at random: uncoated stents, stents coated with PLLA or stents coated with As(2)O(3) in PLLA. Animals were euthanized 28 days after stent implantation into the iliac arteries of rabbits. Neointimal thicknesses and apoptosis of vascular smooth muscle cell (VSMC) were measured. Stents coated with As(2)O(3) in PLLA were implanted in another 48 male New Zealand white rabbits, As(2)O(3) concentrations in serum and arterial tissue at implantation site were measured at 2 h and 1, 3, 7, 14, 28 days after As(2)O(3) eluting stent implantation (n = 8 for each time point). Neointimal hyperplasia was significantly reduced 51% and 31% and apoptosis significantly increased (21.0 +/- 3.3; 6.2 +/- 1.9(*); 5.3 +/- 2.1(*), (*)P < 0.01 vs. As(2)O(3) eluting stent) with As(2)O(3) eluting stent, versus PLLA-coated stents and uncoated stents. As(2)O(3) concentrations in arterial tissue at implantation site were 18.6 +/- 9.1 (ng/mg) at 1 day and 0.3 +/- 0.1 (ng/mg) at 28 days after stent implanta...Continue Reading

Related Concepts

Related Feeds

Apoptosis

Apoptosis is a specific process that leads to programmed cell death through the activation of an evolutionary conserved intracellular pathway leading to pathognomic cellular changes distinct from cellular necrosis