PMID: 16623406Apr 21, 2006Paper

Cardioversion corrects cardiac arrhythmia and reverts the resultant reversed shunt flow direction during transcatheter closure of atrial septal defect--a case report

Acta Anaesthesiologica Taiwanica : Official Journal of the Taiwan Society of Anesthesiologists
Chia-Chan WuChih-Peng Lin

Abstract

Closure of atrial septal defect (ASD) is critically dependent on the shunt flow direction. However, shunt flow direction through ASD may change under variable clinical conditions. We present here a 53-year-old woman with a confirmed left-to-right shunt ASD prior to Amplatzer Septal Occluder placement. The development of atrial flutter during the procedure had been found to change the shunt from unidirectional to bidirectional and the procedure was then forced to a temporary halt. The cardiac arrhythmia and altered shunt direction simultaneously reverted to the old state after cardioversion. A successful placement of Amplatzer septal occluder was successfully performed afterward and she recovered uneventfully.

Related Concepts

Related Feeds

Atrial Fibrillation

Atrial fibrillation is a common arrhythmia that is associated with substantial morbidity and mortality, particularly due to stroke and thromboembolism. Here is the latest research.

Arrhythmia