Cost analysis of the flash monitoring system (FreeStyle Libre 2) in adults with type 1 diabetes mellitus.
Abstract
Compare cost of the interstitial liquid glucose flash monitoring (FM) system (FreeStyle Libre 2) versus self-monitoring of blood glucose (SMBG) in adults with type 1 diabetes mellitus (T1DM) in Spain. A model was developed to estimate, with the perspective of the Spanish health system, the annual costs associated with glucose monitoring and hypoglycemic events management in T1DM population, with multiple insulin daily doses (MDI). According to published evidence, rate of severe hypoglycemia (SHE) of 4.90 episodes per patient-year was applied. Reduction of SHE (58.6%) was modeled associated with FM use. Published rates of hospital care (20.2%) and subsequent admission (16%) were assumed for SHE. The daily consumption of strips and lancets was 9 in patients with SMBG (before and after 4 daily intakes and at bedtime) and 0.5 for FM users (according to IMPACT trial findings). Annual consumption of 26 FM sensors was considered (1 every 14 days). Unit costs (in € of 2019, excluding VAT) were obtained from literature and national databases. Sensitivity analyses (SA) were carried out to evaluate the model robustness. The total annual cost/patient was €4437 for SMBG and €2526 for FM. The use of FM would be associated with an annual savi...Continue Reading
References
Citations
Software Mentioned
Related Concepts
Related Feeds
American Diabetes Association Journals