Abstract
This paper reports the novel design of a touch mode capacitive pressure sensor (TMCPS) system with a wireless approach for a full-range continuous monitoring of ventricular pressure. The system consists of two modules: an implantable set and an external reading device. The implantable set, restricted to a 2 × 2 cm² area, consists of a TMCPS array connected with a dual-layer coil, for making a reliable resonant circuit for communication with the external device. The capacitive array is modelled considering the small deflection regime for achieving a dynamic and full 5⁻300 mmHg pressure range. In this design, the two inductive-coupled modules are calculated considering proper electromagnetic alignment, based on two planar coils and considering the following: 13.56 MHz frequency to avoid tissue damage and three types of biological tissue as core (skin, fat and muscle). The system was validated with the Comsol Multiphysics and CoventorWare softwares; showing a 90% power transmission efficiency at a 3.5 cm distance between coils. The implantable module includes aluminum- and polyimide-based devices, which allows ergonomic, robust, reproducible, and technologically feasible integrated sensors. In addition, the module shows a simplifi...Continue Reading
References
Mar 15, 1992·Journal of the American College of Cardiology·G C FonarowE Albanese
Feb 1, 1991·The American Journal of Cardiology·M A HamiltonM Woo
Dec 1, 1986·Circulation·L W Stevenson, J H Tillisch
Jun 1, 1967·American Journal of Surgery·E R OlsenD W Pinto
Apr 1, 1967·IEEE Transactions on Bio-medical Engineering·C C Collins
Sep 1, 1997·Journal of the American College of Cardiology·G C FonarowM A Woo
May 23, 2002·Journal of Cardiac Failure·Anthony MagalskiTom Bennett
Feb 25, 2003·Journal of the American College of Cardiology·Philip B AdamsonTom Bennett
Jun 14, 2005·The Journal of Heart and Lung Transplantation : the Official Publication of the International Society for Heart Transplantation·Luca LanzariniCatherine Klersy
Feb 14, 2006·Congestive Heart Failure·Philip B AdamsonTom Bennett
Aug 15, 2006·Health Technology Assessment : HTA·S HarveyK Rowan
Aug 19, 2007·Heart·Arend Mosterd, Arno W Hoes
Dec 25, 2007·Journal of the American College of Cardiology·Hugo E VerdejoRobert C Bourge
Jan 12, 2008·Journal of the American Society of Echocardiography : Official Publication of the American Society of Echocardiography·Peter S Rahko
Sep 17, 2008·Circulation·Michael R ZileRobert C Bourge
Oct 13, 2010·Cardiology Clinics·Gbenga Ogedegbe, Thomas Pickering
Dec 16, 2010·Circulation. Arrhythmia and Electrophysiology·Faisal M MerchantJagmeet P Singh
Jun 22, 2014·Biomedical Engineering Online·Mahammad A HannanAini Hussain
Jul 2, 2014·Sensors·Saad MutasharAini Hussain
Aug 7, 2014·TheScientificWorldJournal·Adrian E Rendon-NavaDaniela Díaz-Alonso
Sep 24, 2014·Sensors·Ingelin Clausen, Thomas Glott
Nov 13, 2015·Lancet·William T AbrahamUNKNOWN CHAMPION Trial Study Group
May 11, 2018·Salud pública de México·Ismael Campos-NonatoSimón Barquera
May 12, 2018·Circulation. Cardiovascular Interventions·Thomas MondritzkiHubert Truebel
Jun 18, 2018·Hipertensión y riesgo vascular·J R Banegas, L M Ruilope
Citations
Oct 28, 2019·Sensors·Jia-Lin YaoXing Yang
Jul 2, 2020·Sensors·Jiuk JangJang-Ung Park
Oct 2, 2019·Materials·Catalin P ConstantinRadu D Rusu
Mar 14, 2020·Sensors·Natiely Hernández SebastiánWilfrido Calleja Arriaga
May 1, 2021·Sensors·Ruth Yadira Vidana MoralesRicardo Casas Carrillo
Aug 3, 2021·Sensing and Imaging·Mahdieh KhorsandifardArash Sheikhaleh