Diagnostic accuracy of magnetic resonance imaging in assessing placental adhesion disorder in patients with placenta previa: Correlation with histological findings

European Journal of Radiology
S MaureaA Brunetti

Abstract

To evaluate MRI accuracy in assessing placental adhesion disorders (PAD) in patients with placenta previa correlating imaging results with histological findings. Sixty-one patients who underwent abdomino-pelvic magnetic resonance imaging (MRI) for ultrasound suspicion of PAD were prospectively evaluated. T1- and T2-weighted images, with and without fat suppression, were obtained in the three conventional planes using a 1.5 T MRI scanner. MRI accuracy to evaluate the presence of PAD was assessed on the basis of the occurrence of the following abnormal MRI signs: 1) intraplacental dark bands; 2) focal interruption of myometrial border; 3) intraplacental abnormal vascularity; 4) uterine bulging; 5) tenting of the bladder and/or 6) direct visualization of adjacent tissues invasion only in case of percretism. Imaging results were classified as suggestive or not of PAD using histological data as standard of reference; two methods of imaging analysis were used represented by the presence of at least one (Method A) or two (Method B) abnormal MRI signs; the correlation between the presence of each abnormal MRI sign of PAD and the corresponding histological finding was also assessed. The accuracy, as the area under the receiver operating...Continue Reading