Abstract

This prospective study investigated the effects of fold-over oversampling on phase-offset background errors with 2D-Cine phase contrast (Cine-PC) magnetic resonance imaging (MRI). It was performed on brain MRI and compared to conventional Full-field of view FOV coverage and it was tested with two different velocity encoding (Venc) values. We chose Venc = 100 mm/s to encode cerebrospinal fluid (CSF) flows in the aqueduct and 600 mm/s to encode blood flow in the carotid artery. Cine-PC was carried out on 10 healthy adult volunteers followed simultaneously by an acquisition on static agar-gel phantom to measure the phase-offset background errors. Pixel-wise correction of both the CSF and the blood flows was calculated through 32 points of the cardiac-cycle. We compared the velocity-to-noise ratio, the section area, the absolute and the corrected velocity (peak; mean and minimum), the net flow, and the stroke volume before and after correction. We performed the statistical T-test to compare Full-FOV and fold-over and Bland-Altman plots to analyze their differences. Our results showed that following phase-offset error correction, the blood stroke-volume was significantly higher with Full-FOV compared to fold-over. We observed a sign...Continue Reading

References

May 1, 1996·Journal of Magnetic Resonance Imaging : JMRI·G Z YangD N Firmin
Dec 16, 2004·Magma·R WinkelmannO Dössel
Sep 29, 2009·Magnetic Resonance in Medical Sciences : MRMS : an Official Journal of Japan Society of Magnetic Resonance in Medicine·Keita YoshidaKenya Murase
Jan 16, 2010·Journal of Cardiovascular Magnetic Resonance : Official Journal of the Society for Cardiovascular Magnetic Resonance·Peter D GatehousePhilip J Kilner
Mar 9, 2010·Journal of Cardiovascular Magnetic Resonance : Official Journal of the Society for Cardiovascular Magnetic Resonance·Brian J HollandWyman W Lai
Feb 22, 2011·Respiratory Care·Victor A ConvertinoKeith G Lurie
Feb 22, 2011·Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine·Petter DyverfeldtTino Ebbers
Feb 26, 2011·Fluids and Barriers of the CNS·Mark E WagshulJoseph R Madsen
Aug 10, 2011·Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine·Daniel GieseSebastian Kozerke
Dec 19, 2013·Journal of Child Neurology·Cyrille CapelOlivier Balédent
Jan 8, 2015·Journal of Cerebral Blood Flow and Metabolism : Official Journal of the International Society of Cerebral Blood Flow and Metabolism·Laleh ZarrinkoobJan Malm
Jun 26, 2015·Biochemia Medica·Davide Giavarina
Jul 9, 2016·Acta Neurologica Scandinavica·S QvarlanderA Eklund
Nov 16, 2018·Magnetic Resonance in Medicine : Official Journal of the Society of Magnetic Resonance in Medicine·Aaron A PruittRizwan Ahmad

❮ Previous
Next ❯

Software Mentioned

Cine
PC
SPSS

Related Concepts

Related Feeds

CSF & Lymphatic System

This feed focuses on Cerebral Spinal Fluid (CSF) and the lymphatic system. Discover the latest papers using imaging techniques to track CSF outflow into the lymphatic system in animal models.

Related Papers

Medical & Biological Illustration
C H BARNETT
Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology
M Geraldine ZunigaRobert F Labadie
Journal of Magnetic Resonance Imaging : JMRI
D J LarkmanJ V Hajnal
International Journal of Pediatric Otorhinolaryngology
Luluh AlsughayerAbdulrahman Hagr
Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology
Jennis GabrielpillaiSilke Helbig
© 2022 Meta ULC. All rights reserved