Hybrid 99m Tc-magnetite tracer for dual modality sentinel lymph node mapping
Abstract
Accuracy of sentinel lymph node identification using radioactive tracers in non-superficial cancers can be limited by radiation shine through and low spatial resolution of detection systems such as intraoperative gamma probes. By utilising a dual radioactive/magnetic tracer, sensitive lymphoscintigraphy can be paired with high spatial resolution intraoperative magnetometer probes to improve the accuracy of sentinel node detection in cancers with complex multidirectional lymphatic drainage. Dextran-coated magnetite nanoparticles (33 nm mean hydrodynamic diameter) were labelled with 99mTc and applied as a lymphotropic tracer in small and large animal models. The dual tracer could be radiolabelled with 98 ± 2% efficiency after 10 min of incubation at room temperature. Biodistribution studies of the tracer were conducted in normal rats (subdermal and intravenous tail delivery, n = 3) and swine (subdermal hind limb delivery, n = 5). In rats the dual tracer migrated through four tiers of lymph node, 20 min after subdermal injection. Results from intravenous biodistribution test for radiocolloids demonstrated no aggregation in vivo, however indicated the presence of some lower-molecular weight radioactive impurities (99mTc-dextran). I...Continue Reading