Quantitative determination of fentanyl in newborn pig plasma and cerebrospinal fluid samples by HPLC-MS/MS
Abstract
In this study, a selective and sensitive high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method requiring low sample volume (≤100 μL) was developed and validated for the quantitative determination of the opioid drug fentanyl in plasma and cerebrospinal fluid (CSF). A protein precipitation extraction with acetonitrile was used for plasma samples whereas CSF samples were injected directly on the HPLC column. Fentanyl and (13) C6 -fentanyl (Internal Standard) were analyzed in an electrospray ionization source in positive mode, with multiple reaction monitoring (MRM) of the transitions m/z 337.0/188.0 and m/z 337.0/105.0 for quantification and confirmation of fentanyl, and m/z 343.0/188.0 for (13) C6 -fentanyl. The respective lowest limits of quantification for plasma and CSF were 0.2 and 0.25 ng/mL. Intra- and inter-assay precision and accuracy did not exceed 15%, in accordance with bioanalytical validation guidelines. The described analytical method was proven to be robust and was successfully applied to the determination of fentanyl in plasma and CSF samples from a pharmacokinetic and pharmacodynamic study in newborn piglets receiving intravenous fentanyl (5 µg/kg bolus immediately followed by a 90-m...Continue Reading
References
Determination of fentanyl in human plasma and fentanyl and norfentanyl in human urine using LC-MS/MS
Citations
Related Concepts
Related Feeds
CSF & Lymphatic System
This feed focuses on Cerebral Spinal Fluid (CSF) and the lymphatic system. Discover the latest papers using imaging techniques to track CSF outflow into the lymphatic system in animal models.