SU-E-T-403: Delivery Efficiency of StereoArc Stereotactic Body Radiotherapy (SBRT)

Medical Physics
E KinseyByongyong Yi

Abstract

Traditional SBRT employs approximately 10 static beams with up to 20 Gy per fraction, requiring lengthy treatments which can be difficult for patients to tolerate, increasing the risk of movement, and causing discrepancies in the reproducibility of the breathing cycle. Commercial VMAT systems offer shorter treatment times with modulated beams; however, modulation is often not necessary or desired for small fields. Conformai arc therapy offers efficient beam delivery, but with only one aperture shape and constant beam weighting over all gantry angles. This study evaluates the efficiency of a new SBRT delivery Method: a conformai arc with multiple aperture shapes and variable dose rate. Three clinical SBRT cases were chosen for this study. Each static field was converted into an arc segment to create a StereoArc plan. Gantry angle ranges were determined from the clinical monitor units, with the MU/degree chosen to maximize the dose rate. All segments were merged into a single arc with variable dose rate. Dose distributions from the StereoArc plans were compared to the clinical static field plans using Pinnacle. Delivery times were compared between the static SBRT plans, both with and without Beam Automation, and equivalent Stereo...Continue Reading

Related Concepts

Related Feeds

Buruli Ulcer

Buruli ulcer is a progressive disease of subcutaneous tissues caused by mycobacterium ulcerans. Here is the latest research.