A three-dimensional biofilm-electrode reactor (3D-BER) was constructed to facilitate the tertiary denitrification of the secondary effluent of wastewater treatment plants (SEWTP) under 12 mA and in the absence of a carbon source. The TN removal efficiency was 63.8%. The path of the formation and transformation of nitrogen, the relationship between the TN and COD removal rate and the relative concentration and composition of organic matter in the influent and effluent were analyzed to clarify the possible pathways of N and C transformation in the 3D-BER system. Under the action of an electric current, 4.4 mg NH4+-N·L-1 and 17.7 mg COD·L-1 accumulated in the 3D-BER system, and the removal rates of TN and COD were strongly and positively correlated (R2 = 0.9353). The microorganisms in the 3D-BER system under the action of electric current secreted organic matter, some of which (humic acid and microbial metabolites) could be further electrolyzed by microorganisms into bioavailable organic matter for heterotrophic denitrification. Partially dissolved organic matter (DOM, tryptophan aromatic protein, humic acid and microbial metabolites) in the SEWTP could be hydrolyzed under the action of the electric current in the 3D-BER system an...Continue Reading

Related Concepts

Related Feeds

Biofilm & Infectious Disease

Biofilm formation is a key virulence factor for a wide range of microorganisms that cause chronic infections.Here is the latest research on biofilm and infectious diseases.