PMID: 26775376Jan 19, 2016Paper

The evaluation of hypermetabolic mediastinal-hilar lymph nodes determined by PET/CT in pulmonary and extrapulmonary malignancies: correlation with EBUS-TBNA

Turkish Journal of Medical Sciences
Zuhal KandemirSeyda Türkölmez

Abstract

We aimed to define the optimal SUV(max) cut-off value in determination of mediastinal-hilar lymph node metastasis, by comparing positive PET/CT results with the results of endobronchial ultrasound guided transbronchial needle aspiration biopsy (EBUS-TBNA). Thirty-one patients with malignancy whose PET/CT imaging revealed a hypermetabolic mediastinal and/or hilar lymph node and who had undergone EBUS-TBNA were evaluated retrospectively. Histopathology was regarded as the gold standard. The diagnostic role of PET/CT in mediastinal/hilar lymph node metastasis was investigated and compared with the results of contrast-enhanced CT. When a SUV(max) value of 2.5 was used, the sensitivity, positive predictive value (PPV), and diagnostic accuracy of the PET/CT were 100%, 65.4%, and 65.4% respectively. In the ROC analysis, the SUV(max) cut-off value with the highest diagnostic accuracy (75%) was calculated as 6.3, and when this value was considered, the sensitivity, specificity, PPV, negative predictive value, and diagnostic accuracy of the PET/CT were determined as 70.6%, 83.3%, 88.9%, 60%, and 75% respectively (AUC: 0.779). The sensitivity, PPV, and diagnostic accuracy of the thorax CT were calculated as 91.1%, 72%, and 71.1%, respecti...Continue Reading

Related Concepts

Related Feeds

Cancer Imaging