PMID: 15227316Sep 1, 1987Paper

Transannular GORE-TEX patch with pericardial unicusp for total correction of tetralogy of fallot

Texas Heart Institute Journal
R V CanentK W Ashcraft

Abstract

When corrective surgery for tetralogy of Fallot was accomplished through the use of a transannular GORE-TEX patch with a pericardial unicusp, the right-ventricular end-diastolic volumes of all patients studied within a year of the surgery were within the normal ranges because of decreased pulmonary valve regurgitation. The right-ventricular ejection fraction was also only slightly depressed, indicating preservation of right-ventricular function. All patients were noted to maintain normal stroke volumes and normal systolic indices. In contrast, the patients who had transannular patches placed without unicusps showed significantly elevated right-ventricular end-diastolic volumes and lower right-ventricular ejection fractions. These resulted from markedly dilated right-ventricular outflow regions in conjunction with enlarged right-ventricular chambers, which manifested as large dyskinetic areas in the anterior right-ventricular walls.

Related Feeds

Birth Defects

Birth defects encompass structural and functional alterations that occur during embryonic or fetal development and are present since birth. The cause may be genetic, environmental or unknown and can result in physical and/or mental impairment. Here is the latest research on birth defects.