Abstract

Although the majority of patients undergoing defibrillation suffer from coronary heart disease, little is known about defibrillation in the setting of ischemic disease. The goal of this study is to aid understanding of defibrillation failure in ischemic hearts by studying changes in cardiac vulnerability to electric shocks the first 10 min following LAD occlusion. To do so, a 3D anatomically-accurate electrophysiologically-detailed bidomain model of the regionally ischemic ventricles following LAD occlusion was developed based on experimental data. The ventricles were paced at the apex and truncated exponential monophasic shocks were applied over a range of coupling intervals to determine the upper limit of vulnerability (ULV) and the vulnerable window (VW) in normoxia and 10 min post-occlusion. Simulation results demonstrate that, despite the profound electrophysiological changes in the ischemic region, the ULV remains unchanged 10 min post-occlusion because following high shock strengths gesULV virtual electrode polarization and postshock behavior remain unaffected by ischemia. However, the range of coupling intervals comprising the VW increases from spanning 60 ms in normoxia to 90 ms at 10 min post-occlusion. The increased ...Continue Reading

  • References
  • Citations

References

  • We're still populating references for this paper, please check back later.
  • References
  • Citations

Citations

  • This paper may not have been cited yet.

Mentioned in this Paper

Ischemia
In Silico
Leukocyte Adhesion Deficiency Type 1
Left Ventricular Structure
Ventricular Dysfunction, Left
Shock
Myocardial Ischemia
Coronary Arteriosclerosis
Obstruction
Cardiac Conduction System

Related Feeds

Brain-Computer Interface

A brain-computer interface, also known as a brain-machine interface, is a bi-directional communication pathway between an external device and a wired brain. Here is the latest research on this topic.

Cardiac Conduction System

The cardiac conduction system is a specialized tract of myocardial cells responsible for maintaining normal cardiac rhythm. Discover the latest research on the cardiac conduction system here.

Related Papers

American Journal of Physiology. Heart and Circulatory Physiology
Blanca RodríguezNatalia Trayanova
Conference Proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society
T MaharajDavid Gavaghan
© 2020 Meta ULC. All rights reserved